EPA 0010Modified Method 5 Sampling Train

EPA 0010Modified Method 5 Sampling Train

ID:44076279

大小:686.70 KB

页数:50页

时间:2019-10-18

EPA 0010Modified Method 5 Sampling Train_第1页
EPA 0010Modified Method 5 Sampling Train_第2页
EPA 0010Modified Method 5 Sampling Train_第3页
EPA 0010Modified Method 5 Sampling Train_第4页
EPA 0010Modified Method 5 Sampling Train_第5页
资源描述:

《EPA 0010Modified Method 5 Sampling Train》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库

1、METHOD0010MODIFIEDMETHOD5SAMPLINGTRAIN1.0SCOPEANDAPPLICATION1.1ThismethodisapplicabletothedeterminationofDestructionandRemovalEfficiency(DRE)ofsemivolatilePrincipalOrganicHazardousCompounds(POHCs)fromincinerationsystems(PHS,1967).Thismethodalsomaybeusedtodetermineparticulateemissionratesfromstationa

2、rysourcesasperEPAMethod5(seeReferencesatendofthismethod).2.0SUMMARYOFMETHOD2.1Gaseousandparticulatepollutantsarewithdrawnfromanemissionsourceatanisokineticsamplingrateandarecollectedinamulticomponentsamplingtrain.Principalcomponentsofthetrainincludeahigh-efficiencyglass-orquartz-fiberfilterandapacke

3、dbedofporouspolymericadsorbentresin.Thefilterisusedtocollectorganic-ladenparticulatematerialsandtheporouspolymericresintoadsorbsemivolatileorganicspecies.Semivolatilespeciesaredefinedascompoundswithboilingpoints>100EC.2.2Comprehensivechemicalanalysesofthecollectedsampleareconductedtodeterminetheconc

4、entrationandidentityoftheorganicmaterials.3.0INTERFERENCES3.1Oxidesofnitrogen(NOx)arepossibleinterferentsinthedeterminationofcertainwater-solublecompoundssuchasdioxane,phenol,andurethane;reactionofthesecompoundswithNOxinthepresenceofmoisturewillreducetheirconcentration.Otherpossibilitiesthatcouldres

5、ultinpositiveornegativebiasare(1)stabilityofthecompoundsinmethylenechloride,(2)theformationofwater-solubleorganicsaltsontheresininthepresenceofmoisture,and(3)thesolventextractionefficiencyofwater-solublecompoundsfromaqueousmedia.Useoftwoormoreionspercompoundforqualitativeandquantitativeanalysiscanov

6、ercomeinterferenceatonemass.Theseconcernsshouldbeaddressedonacompound-by-compoundbasisbeforeusingthismethod.4.0APPARATUSANDMATERIALS4.1Samplingtrain:4.1.1AschematicofthesamplingtrainusedinthismethodisshowninFigure1.ThissamplingtrainconfigurationisadaptedfromEPAMethod5procedures,and,assuch,themajorit

7、yoftherequiredequipment00101CD-ROMRevision0DateSeptember198600102CD-ROMRevision0DateSeptember1986isidenticaltothatusedinEPAMethod5determinations.Thenewcomponentsrequiredareacondensercoilandasorbentmod

当前文档最多预览五页,下载文档查看全文