EPA METHOD 3585 Waste Dilution for Volatile Organics

EPA METHOD 3585 Waste Dilution for Volatile Organics

ID:44077058

大小:44.08 KB

页数:4页

时间:2019-10-18

EPA METHOD 3585 Waste Dilution for Volatile Organics_第1页
EPA METHOD 3585 Waste Dilution for Volatile Organics_第2页
EPA METHOD 3585 Waste Dilution for Volatile Organics_第3页
EPA METHOD 3585 Waste Dilution for Volatile Organics_第4页
资源描述:

《EPA METHOD 3585 Waste Dilution for Volatile Organics》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库

1、METHOD3585WASTEDILUTIONFORVOLATILEORGANICS1.0SCOPEANDAPPLICATION1.1Thismethoddescribesasolventdilutionofanon-aqueouswastesamplepriortodirectinjectionanalysis.ItisdesignedforuseinconjunctionwithGCorGC/MSanalysisofwastesthatmaycontainorganicchemicalsataconce

2、ntrationgreaterthan1mg/kgandthataresolubleinthedilutionsolvent.Method3585hasadequatesensitivitytodeterminetheregulatoryconcentrationsoftheToxicityCharacteristic(TC)Rule.1.2Thismethodmaybeusedwithn-hexadecanefordirectinjectionoftargetvolatilesinoilymatrices

3、.1.3Useofa1-2µLinjectionofa1:1dilutioncanbeusedtoprovidedetectionlimitsof0.5ppmforvolatiletargetanalyteswithasensitiveGC/MS.1.4Thismethodisrestrictedtousebyorunderthesupervisionoftrainedanalysts.Eachanalystmustdemonstratetheabilitytogenerateacceptableresul

4、tswiththismethod.2.0SUMMARYOFMETHOD2.1Highlycontaminatedorhighlycomplexsamplesmaybedilutedpriortoanalysisforvolatilesusingdirectinjection.2.2Onegramofsampleisweighedintoacappedtubeorvolumetricflask.Thesampleisdilutedto2.0-10.0mLwithn-hexadecaneorotherappro

5、priatesolvent.2.3DilutedsamplesareinjectedintotheGCorGC/MSforanalysis.3.0INTERFERENCES3.1Useofadirectinjectionprocedurewillresultinconsiderablecontaminationofinjectionports,injectionportliners,GCcolumns,anddetectors.APyrex®woolplugshouldbeplacedintotheinje

6、ctionportlinerandthelinershouldbechangedafterevery12hoursofsampleanalysis.3.2Thesolventusedforwastedilutionmaycontainvolatilecontaminantsthatcouldinterferewithanalyses.3.2.1n-Hexadecaneelutesaftertargetvolatiles.However,volatileimpuritiesinn-hexadecanemayi

7、nterferewithanalyses.3.2.2Eachlotofn-hexadecane(oranyothersolventusedfordilution)mustbeanalyzedforimpuritiespriortouse.3.3Thepresenceofmethanolandotheroxygenatedsolventsinsamplesmayleadtobaselinehumpsthatinterferewithqualitativeandquantitativeanalysisofear

8、lyelutingtargetanalyteswhendirectinjectionisemployed.CD-ROM3585-1Revision0December19964.0APPARATUSANDMATERIALS4.1Glassscintillationvials-Atleast20-mL,withpolytetrafluoroethylene(PTFE)-oraluminumfoil-linedscre