1、MaintenanceforJuniperRouterObservetheLEDonpanelThedebugcommandsincommonusedSomebasicdebugmethodsSomesuggestionaboutinspectLEDStatusInterfacesLEDRouting-engineLEDnormal/inusedfaultAlarmsLEDThedebugcommandsincommonused1.Checkthetemperaturethresholds:showchassistemperature-thresholdsFanspeedYellow

2、alarmRedalarmItemNormalHighNormalBadfanNormalBadfanChassisdefault485465557565RoutingEngine55658585100100Acquiescently,thetemperatureofrouting-enginenohigherthan65℃,thetemperatureofchassisnohighthan54℃.gobeyondthethresholdwouldtriggeralarms.2.Checkthesystemalarmmessage:showchassisalarms1alarmscu

3、rrentlyactiveAlarmtimeClassDescription2007-09-1909:05:39UTCMajorHost0fxp0:EthernetLinkDownthiscommandshowsalltypeoferroroverthesystem.Forexample,thelinkfailure/temperatureoverhigh/hardwaredowncouldbeenloggedbysystem.thisisaimportanttoolswheninspectthestateofdevice.3.Checkthesystemtemperatureand

4、componentsstatus:showchassisenvironmentClassItemStatusMeasurementPowerPowerSupply0OKPowerSupply1OKPowerSupply2AbsentPowerSupply3AbsentTempIntakeOK23degreesC/73degreesFFPC0OK25degreesC/77degreesFFPC1OK25degreesC/77degreesFLowerPowerSuppliesOK24degreesC/75degreesFUpperPowerSuppliesOK24degreesC/75

5、degreesFUpperPowerSuppliesOK24degreesC/75degreesFCFEBIntakeOK25degreesC/77degreesFCFEBExhaustOK33degreesC/91degreesFRoutingEngine0OK25degreesC/77degreesFRoutingEngine1Absent3.Displaythesystemtemperatureandcomponentsstatus(cont):FansFanTray0AbsentFanTray1Fan1OKSpinningatnormalspeedFanTray1Fan2OK

6、SpinningatnormalspeedFanTray1Fan3OKSpinningatnormalspeedFanTray1Fan4OKSpinningatnormalspeedFanTray1Fan5OKSpinningatnormalspeedFanTray1Fan6OKSpinningatnormalspeedFanTray1Fan7OKSpinningatnormalspeedFanTray1Fan8OKSpinningatnormalspeedThecommanddisplaythestateofchassiscomponents.Forinstance,PowerSu

7、pply0isthepowerlocateatslot1,PowerSupply1isthepowerlocateatslot2.Anyway,thestateofdeviceshoulddisplay“OK”.Iftheslotisempty,display“Absent”.4.ChecktheCPUutilizationpercent:showsystemprocessessummarylastpid:68788;loadaverages:0.01,0