思科CCNA题目及答案

思科CCNA题目及答案

ID:37356008

大小:179.98 KB

页数:27页

时间:2019-05-22

思科CCNA题目及答案_第1页
思科CCNA题目及答案_第2页
思科CCNA题目及答案_第3页
思科CCNA题目及答案_第4页
思科CCNA题目及答案_第5页
资源描述:

《思科CCNA题目及答案》由会员上传分享,免费在线阅读,更多相关内容在教育资源-天天文库

1、CCNA-Cisco-Chapter11C11Anelectricianhasinvestigatedyourrecentpowerproblemsandhassuggestedthattheyarecausedbyoscillation.WhatistheBESTsolutiontoyourproblem?MovethenetworkservertoanotherroomReplaceUTPwithfiberopticcable*RewiretheelectricalsystemFitcommercialsurgesuppresso

2、rs2WhatisanothertermthatcanbeusedtodescribeanIntermediateDistributionFrame(IDF)?workarea(WA)telecommunicationsoutlet(TO)maincross-connect(MCC)*horizontalcross-connect(HCC)3Whyisfiberopticcablecommonlyusedasanetworkbackbonebetweencampusbuildings?Itprovidesalessresistivep

3、athforelectricalcurrenttoflowfromonebuildingtoanotherItenhancesthesignalsatthephysicallayer*ItreducesthehazardouseffectsofelectricalpotentialdifferenceandlightningstrikesItischeaperandeasiertoinstallthancopperwire4Whichofthefollowingenvironmentalspecificationsarerecomme

4、ndedforawiringcloset?Carpetedfloor;tiledwallsandaninwardopeningdoorWoodenfloor;brickwallsandfluorescentlightingTiledfloor;internalpoweroutletsandadroppedceiling*Raisedfloor;woodcoveredwallsandaninternallightswitch5Whatisoneofthemostsignificantcausesofoscillatorynoisepro

5、blemsonapowercircuit????LongwiringrunsSchoolphotocopiersLocatingpowercablesinelevatorshaftsAirconditionerscyclingonandoff6Whatdeviceisbestusedtominimizetheeffectsofpowerlinesagsandbrownouts?AprimaryprotectiondeviceAsurgesuppressorAnopticalisolator*Anuninterruptiblepower

6、supply7WhatcausesElectrostaticDischarge(ESD)?LongpowerlinesFaultyelectricalequipment*AnaccumulationofstaticelectricityAnincreaseinatmospherichumidity8Whichofthefollowingproblemsiscausedbytoohighahumiditylevelinawiringcloset?Signaldegradation*CopperwirecorrosionInsulatio

7、nfailurePowersurges9Whatistheidealroomtemperatureandrelativehumidityatwhichawiringclosetshouldbemaintained?*21degreesCelsius/45%relativehumidity21degreesFahrenheit/45%relativehumidity45degreesCelsius/21%relativehumidity45degreesFahrenheit/21%relativehumidity10Whatisthem

8、aximumlengthspecifiedfor62.5/125µmmultimodeopticalfiberrunbetweentheMDFandIDF?90m800m2000m*3000m11Whataretheth

当前文档最多预览五页,下载文档查看全文

此文档下载收益归作者所有

当前文档最多预览五页,下载文档查看全文
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,天天文库负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。