1、(Feb2003)LIGHTNINGPROTECTIONINSTALLATIONGENERALSPECIFICATION1.SATISFACTORYINSTALLATIONThewholeoftheinstallationshallbecarriedoutinaccordancewith:(a)ThelatestS.A.B.S.CodeofPracticefortheProtectionofStructuresagainstLightning-S.A.B.S.03;SABSIEC61024(1),61024(1-1);SABSIEC61312(1);SABSIEC61662&

2、NRS042.(b)TheKwaZulu-NatalDepartmentofWorksGeneralElectricalSpecification.(c)TheMunicipalBy-LawsandanyotherspecialrequirementsasdeemednecessarybytheLocalSupplyAuthority;(d)LocalFireRegulations.2.S.A.B.S.APPROVEDDRAWINGSSABSApproveddrawingsarenotrequiredforthisproject.3.TESTONCOMPLETIONUponc

3、ompletionofthelightningprotectionsystem,thefollowingtestsshallbewitnessedbyanappointedrepresentativeoftheEmployer.TheresultsshallberecordedonsuitabletestcertificateswhichmustbesignedbyboththeContractorandtheEmployersrepresentative.Asketchmustbeincludedoneachtestcertificateindicatingtheposit

4、ionsofeachearthelectrodeinrelationtosomepermanentreferencepoint.Itmustalsoindicatethepositionsatwhichtestswerecarriedout,thetypeoftestandtheresultsofthesetests.3.1EarthResistanceTestTheEarthResistanceTestshallinvolvemeasuringtheresistancetoearthofeachrod-typeelectrode,orgroupofrod-typeelect

5、rodes,ortrenchearthwhichwouldnormallybeconnectedtoonedown-conductororearthterminal.Thistestmustbemadewiththeelectrodescompletelydisconnectedfromanypartofthestructureorlightningprotectionsystem.3.2ElectricalContinuityTests(a)ExternalDown-ConductorsElectricalcontinuitybetweenthelowerendsofext

6、ernaldown-conductorswhichmustallbedis-connectedfromtheearthingsystemduringthetestshallnotexceed1(one)ohm.(b)MetallicServicesElectricalcontinuitybetweenanymetallicstructuresofservices(e.g.rainwaterpipes)whichformanintegralpartofthelightningprotectionsystemshallnotexceed1(one)ohm.Thesetestssh

7、ouldbecarriedoutwithallothercomponentsofthelightningprotectionsystemdisconnectedfromthecomponentbeingtested.LP/1(Feb2003)4.DESCRIPTIONOFMATERIAL4.1AirTerminalsandDown-conductorsAllconductorsmustbeinaccordancewiththerequirementsofBSS1474orAmericanStandard