2012版本核电子学实验讲义

2012版本核电子学实验讲义

ID:40855275

大小:1.83 MB

页数:40页

时间:2019-08-08

2012版本核电子学实验讲义_第1页
2012版本核电子学实验讲义_第2页
2012版本核电子学实验讲义_第3页
2012版本核电子学实验讲义_第4页
2012版本核电子学实验讲义_第5页
资源描述:

《2012版本核电子学实验讲义》由会员上传分享,免费在线阅读,更多相关内容在行业资料-天天文库

1、《核电子学与核仪器》实验讲义核技术教研室2012年版目录核电子学实验基础·······························································································1实验注意事项·······································································································7实验1闪烁探测器的调试

2、·················································································9实验2线性放大器···························································································14实验3单道脉冲幅度分析器··························································

3、···················19实验4峰值保持器·····························································································24实验5A/D转换电路··························································································30实验6整机仪器的组装及应用··············

4、···························································36核电子学实验基础一、数字示波器的使用1、示波器前面板和用户界面核电子实验室使用的是RIGOLDS5102CA型数字示波器,该示波器的外形见图1。图1RIGOLDS5102CA数字示波器(1)界面认识示波器面板上包括旋钮和功能按键。旋钮的功能与其他示波器类似。显示屏右侧的一列5个灰色按键为菜单操作键(自上而下定义为1号至5号)。通过它们可以设置当前菜单的不同选项。其它按键(包括彩色按

5、键)为功能键,通过它们可以进入不同的功能菜单或直接获得特定的功能应用。图2DS5102CA面板操作操作说明37(2)探头补偿在首次将探头与任一输入通道连接时,需要进行此项调节,使得探头与输入通道相配。未经补偿或补偿偏差的探头会导致测量误差或错误。若需调整探头补偿,请按如下步骤:①将探头菜单中的衰减系数和探头上开关设定为一样的值,都为1X或10X,通常都设为10X,并用探头将通道1和探头补偿器相连。打开通道1,然后按AUTO键自动设置;②检查所显示波形的形状;图3补偿过渡图4正确补偿图5补偿不足③如必要

6、,用非金属质地的改锥调整探头上的可变电容,直到屏幕显示的波形如图4所示的“补偿正确”。2、仪器检查在使用仪器前,通常通过自检信号对仪器做一次快速功能检查,以核实本仪器运行正常。具体步骤如下:(1)接通电源,打开示波器开关,仪器执行所有自检项目,并确认自检;(2)用示波器探头将信号接入通道1(CH1),将探头上的开关设定为10X,并用探头线将通道1与探头补偿器相连;(3)探头设置与示波器中同比例的衰减系数(默认通常设定10X),从而使得测量结果正确反映被测信号的电平;(4)按住AUTO按键几秒钟内,可以

7、看到方波显示(1kHz,峰峰值约3V)。(5)同样的方法检查通道2(CH2),按0FF功能按钮以关闭通道1,按CH2功能按钮以打开通道2,重复步骤2、步骤3步骤4。3、使用实例观测电路中一未知信号,迅速显示和测量信号的频率和峰峰值。(1)迅速显示该信号,请按如下步骤操作:①将探头菜单衰减系数设定为1X,并将探头上的开关设定为1X;②将通道1的探头连接到电路被测点;③按下AUTO(自动设置按钮)。示波器将自动设置使波形显示达到最佳。在此基础上,您可以进一步调节垂直、水平档次,直至波形的显示符合您的要求。

8、37(2)进行自动测量示波器可对大多数显示信号进行自动测量。欲测量信号频率和峰峰值,请按如下步骤操作:①测量峰峰值按下MEASURE按钮以显示自动测量菜单→按下1号菜单操作键以选择信源CH1→按下2号菜单操作键选择测量类型:电压测量→按下2号菜单操作键选择测量参数:峰峰值。此时,您可以在屏幕左下角发现峰峰值的显示。②测量频率按下3号菜单操作键选择测量类型:时间测量→按下2号菜单操作键选择测量参数:频率。此时,您可以在屏幕下方发现频率显示。4、使用要求(1

当前文档最多预览五页,下载文档查看全文

此文档下载收益归作者所有

当前文档最多预览五页,下载文档查看全文
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,天天文库负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。